img
Cable Tracing & Faults Testing 19
·TX2002·
Display 128 x 64 pixel, backlit
CABLE LENGTH METER
Accuracy and Resolution
Ranges @ Vp=70% 220, 440, 870,
Approximately 1% of range
1750 & 3500m
Sensitivity min. 3 pixel return at 4km
CLM-33
Range Selection Automatic range
Velocity Factor Adjustable from 1% to
control
99%
Finest
Accuracy and Resolution
Output Pulse 5Vp-p into open circuit
Approximately 1% of range
Output Impedance Selectable 25, 50,
· Measures Reeled Wire up to 30km
Sensitivity min. 3 pixel return at 2 km
75 & 100 ohms
Velocity Factor Adjustable from 1% to
· Calibration Wire Included
Output Pulse Width 3ns min.
99%
Scan Rate 2 scans per second or scan
Output Pulse 5Vp-p into open circuit
held
Output Impedance Selectable 50, 75 &
Tone Generator Oscillator 810 to
100 ohms
1110Hz
Output Pulse Width 25ns min., 1.6us
Water / Dust Proof IP54
max.
Scan Rate 6.7 scans per second
Tone Generator Oscillator 810 to
1110Hz
Water / Dust Proof IP54
TX2003
BI
The CLM33 quickly measures the
length of reeled wire up to 30km and
· Scans a 6km Cable in Seconds
with gauges from 26AWG to 500MCM.
Within seconds cables can be
measured and digitally displayed
without the cumbersome unrolling of
cable reels. Very useful for electrical
contractors, utilities and distributors to
control inventories of wire.
·CLM33·
Measurement Range
0.1m - 30.00km
The TX2003 is a 6km range time
Cross Section Ranges
domain reflectometer weighing only 350
26AWG to 500MCM
grams. With its 128 x 64 pixel backlit
Basic Accuracy ħ2% of rdg
scratch resistant display, it provides
Resistance 0 - 99.99ohm
accurate and easy to read fault
4 digit display with annunciators.
locations on metallic cables. With a 3
Measurement METERS(m) or FEET(ft)
nano second pulse rise time, "near end"
User Select Mode allows users to save
cable faults can be clearly identified
the resistance of a known wire for
without the need to supress the
additional measurements of unknown
transmitted pulse. Housed in a rugged
lengths of the same gauge wire.
IP54 rated ABS enclosure, the TX2003
Direct Readout for both COPPER(Cu)
is suitable for outside use.
or ALUMINUM(Al)wire
Milliohm Meter Mode
Using pre-determined gain and pulse
Resistance Range for milliohm
widths for each range setting and with
measurements
only 4 control buttons, all major
Automatic internal temperature
operating and setting parameters can
compensation for changes in
be easily accessed. A 6km cable run
ambient temperature.
can be scanned in seconds, allowing
User calibration mode
the operator a view of the cable run, yet
Calibration standard wire included.
quickly arrive at the fault.
Low battery indicator
Includes Kelvin clips(test leads)
·TX2003·
Ranges @ Vp=70% 7m, 15m, 30m,
60m, 120m, 250m, 500m, 1km, 2km,
3km and 6km
Range Selection manual range control
· SA Tel 8363 5733
· WA Tel 9361 4200
TOLL FREE 1800 632 953
· EMONA Instruments ·