img
Production Testers & PCB Fault Locators 12
AC Voltage Range 0.1-5kV, 2V Steps
·TOS5052·
GW MANUAL PRODUCTION
DC Voltage Range 0.1-6kV, 2V Steps
Output Voltage 0.5-5kV AC
SAFETY TESTERS
Insulation Resistance
Setting Accuracy ±(2% of setting +2
50V to 1000V in 50V Steps
digits) at 0.2kV or higher with no load
GPT-9804 5kV AC/DC
1Mohm to 9,500Mohm
Resolution 10V
DUT Short/Open Circuit Test
GW Instruments
Output Type PWM switching
Arc Detection
Controllable Voltage Ramp Up Time
·TOS5051A·
· 5kV AC & 6kV DC Flash Test
Memory 100 memory blocks for AUTO
AC/DC Test 0-2.5kV and 0-5kV
· 30A AC Earth Bond Test
and MANU modes
Maximum Rated Output AC 500VA
Safety INTERLOCK Function
Maximum Rated Output DC 50W
Interfaces USB, RS232, Signal I/O,
Wattage Rating 500VA
GPIB (opt))
Pass/Fail Judgement Function
·TOS5050A·
GPT/GPI-800 Series
AC Voltage output 0-2.5/0-5kV
GW Instruments
Maximum Rated Output AC 500VA
Pass/Fail Judgement Function
· 500VA AC Test Output
The GPI-9804 is GW's new AC/DC
flash tester, that also includes a 30A
· True RMS Current Readback
earth bond test in an economical,
· Simultaneous Display V, A and Time
LEAKAGE CURRENT TESTER
professional package.
·GPT-9804·
GLC-9000
Test Capacity 200VA
GW Instruments
AC Voltage Range 0.1-5kV, 2V Steps
DC Voltage Range 0.1-6kV, 2V Steps
· 50 Pre-Set Test Conditions for Testing
Insulation Resistance
to IEC60990
50V to 1000V in 50V Steps
·GPT/GPI-800 Series·
1Mohm to 9,500Mohm
· Touch Screen For Ease of Use
Product
O/P
AC
DC
IR
Earth Bond 3-30A AC
GPT-805
500VA
Yes
-
-
Open Circuit Earth Bond Test
GPT-815
500VA
Yes
Yes
-
DUT Short/Open Circuit Test
GPI-825
500VA
Yes
-
Yes
Arc Detection
GPI-826
500VA
Yes
Yes
Yes
Controllable Voltage Ramp Up Time
Memory 100 memory blocks for AUTO
Common Specifications:
and MANU modes
ACW Voltage Range 0.1-5kV
Safety INTERLOCK Function
DCW Voltage Range 0.1-6kV
The GLC-9000 Leakage Current Tester
Interfaces USB, RS232, Signal I/O,
Insulation Resistance
is used to perform leakage current (or
GPIB (opt)
500V, 1000V, 1-2000Mohm
touch current) tests on medical
Display V, A,Time Simultaneously
electrical (IEC 60601-1) and 50 pre-set
GPT-9000 Series
Remote I/O 9 pins for START, RESET
test conditions for general purpose
electric & electronic (IEC 60990)
GW Instruments
KIKUSUI MANUAL
equipment. The tester provides 9
PRODUCTION TESTERS
· 200VA AC Test Output
different measurement networks (MD)
to simulate the human body while taking
· Economically Priced AC/DC IR Testers
TOS Series
leakage current measurements in
compliance with the specific standards
Kikusui
or regulations.
·GLC-9000·
DC Ranges 25.00mA to 50.00uA
AC or AC+DC Ranges
25.00mA to 50.00uA
·GPT-9000 Series·
AC Peak 75.0mA to 500.0uA
Product
AC
DC
IR
Equipment Under Test
·TOS5101·
GPT-9801
Yes
-
-
Voltage 85V to 300V
Applied AC/DC Test Voltage
GPT-9802
Yes
Yes
-
Current 0.5A to 10A
0-5kV and 0-10kV
GPT-9803
Yes
Yes
Yes
Meter Mode 300V AC/DC
Maximum Rated Output AC 500VA
430V AC Peak
Maximum Rated Output DC 50W
Interface RS232, GPIB, USB, Ext I/O
Common Specifications:
Pass/Fail Judgement Function
Test Capacity 200VA
· SA Tel 8363 5733
· WA Tel 9361 4200
TOLL FREE 1800 632 953
· EMONA Instruments · 45